Choose a location that meets the following criteria see The autoloader uses standard rack mounting hardware. Page Unpacking The Autoloader 12 hours before opening the shipping carton.
Unpack your new Quantum SuperLoader 3 autoloader carefully and inspect it for any damage that might have occurred during shipping. If you notice any damage, report it to the shipping company immediately. Page Accessories 5 Save the packing materials in case you need to move or ship the autoloader in the future. Turn off all attached accessory devices, such as printers and other SCSI devices. Otherwise, attach the cable to the next device on the SCSI bus.
When the initialization sequence is complete, the LCD screen displays the screen. Turn on any other devices you turned off earlier. Software compatibility information is available at www. Most backup software packages require an additional module to communicate with the autoloader robotics.
There are two device drivers associated with the SuperLoader 3 autoloader. One for the autoloader itself, and a second for the tape drive within the autoloader. Enter Session Complete Note: You can also press as required until the main screen displays.
Warning: If a tape cartridge is holding the mailslot door open on power up, the robot will not move. The cartridge will be about 3 inches 7. This may require that you push and have your fingers well within the mailslot opening.
After insertion, the end of the cartridge will be visible at the back of the mailslot opening. The slot that is occupied by a cleaning tape is indicated with an at One way that you can close the openings is to use two magazines. If you use only one magazine, then you must fill the other magazine opening with a magazine blank for the unit to become operational.
There are two knobs located on each end of the magazine. You can move the slots within the magazine by turning these two knobs and aligning a slot with one of the two openings. You can use the openings in the magazine to load and unload cartridges from the eight slots within each magazine.
It is recommended that you fully remove the magazine to Note: load and unload cartridges. With the magazine removed from the autoloader, you can see the identification mark on the top side of the magazine through one of two windows on the upper surface of the magazine.
The right magazine is present. SAS connection. The configured Fibre Channel connection. The number indicates the Error Correction Code that was generated when the firmware was installed. The autoloader uses this number to verify that the firmware and the memory holding the firmware are good. Version Indicates the version number of the drive. To view the Ethernet information An inventory checks each magazine slot, the drive, the picker, and the mailslot to determine if a cartridge is present.
Use of the Remote Management should not be issued while the autoloader is being used by host applications. To select the Fibre Channel parameters: 1 From any page, click the screen displays. To set the parameters: 1 From any page, click the screen displays. To change the selection, select the other option. The front panel and On-board Remote Management will display whether or not compression is enabled. This setting must match the physical configuration in order for correct information to be reported.
This setting only affects the information reported to the SCSI host. For example, if you live in Colorado, the time difference is Note: —6 hours in the summer and —7 hours in the winter. To change a static IP address, type in the new address in the IP address fields using the from box to box.
If a single set is enabled, only clients that pass the test specified by that set are allowed administrator access. If both sets are enabled, any client that passes either of the two filter tests can administer the unit.
To get system updates: 1 From any page, click the screen displays. Diagnostics You can also view error and history logs, test progress, identify the physical unit in a rack, or reset the system. Commands From a remote location, you can request that a tape be moved from one position to another.
Page Sequential Operations 3 To start Sequential Operations available cartridge from the storage slot to the drive. Page Configuring The Autoloader However, after you set the security option, all the configuration functionality is password-protected. You need an administrator-level password to configure the autoloader. With an Ethernet connection, you can remotely access the autoloader over the network. New Subnet Mask xxx.
Escape Enter To set an IP gateway The Time Zone cursor automatically appears at the first digit. You will probably use this mode the most. And because you can easily expand from 8 to 16 cartridge slots, your investment is protected as your needs grow.
The primary audience for this document consists of end users installing and using the SuperLoader 3 autoloader. Preparation Before you install your new SuperLoader, unpack it carefully and inspect it for any damage that might have occurred during shipping.
The SuperLoader Quick Start Guide included in the packaging describes all the necessary information to unpack and inspect your SuperLoader correctly. LUN data storage device. View and Download Quantum SuperLoader 3 user manual online. Front Alignment Location Criteria Front Panel LEDs Autoloader Status Firmware Version Fields Drive Status Fields Drive Version Fields Ethernet Information Fields POST Descriptions Log Retrieval Methods Log Field Descriptions This document serves as an easy-to-use information source to familiarize Quantum customers and systems professionals with the SuperLoader 3 autoloader.
Note: Notes emphasize important information related to the main topic. Warning: Warnings indicate potential hazards to personal safety and are included to prevent injury.
Copies may be obtained from:. To order documentation on the SuperLoader 3 Autoloader or other products, contact:. Accelerate service issue resolution with these exclusive Quantum StorageCare services:. Benefit today at: www. Online Service accounts are free from Quantum. Sign up today at: www. For further assistance, or if training is desired, contact Quantum Technical Assistance Center:.
For the most up to date information on Quantum Global Services, please visit www. Data backup is essential to protect irreplaceable information. Backing up data to magnetic tape is an easy, cost-efficient method used by many small and medium businesses.
However, most enterprises have so much data that a single backup tape is not enough; the information has to be spread across numerous tapes. To avoid constantly changing tapes manually, many tape backup systems include a Quantum SuperLoader 3 autoloader. Each autoloader is a robot that includes a tape drive and one or two magazines for tape cartridges. The user's application can automatically load and unload tape cartridges as required for data backup or data retrieval.
Quantum SuperLoader 3 autoloaders provide a compact, high capacity, but low cost method for simple, unattended data backup. You can also connect to.
Your Quantum SuperLoader 3 contains one of the following tape drives and one or two magazines capable of containing up to eight tape cartridges each. The front panel on the autoloader includes a liquid crystal display LCD screen and four function keys. A scrolling menu on the LCD screen allows you to obtain information from the autoloader and enter commands.
The front panel also includes two light emitting diodes LEDs indicating the autoloader's ready status and error status. A single tape cartridge can be inserted directly into the tape drive via a password-protected mailslot on the front panel provided there is no cartridge already in the drive.
You can also load a tape cartridge into a magazine slot provided there is no cartridge already in the slot. The Quantum SuperLoader 3 LTO-2 autoloader is equipped with a Quantum LTO-2 tape drive and contains up to sixteen Ultrium 2 data cartridges when utilizing two magazines, providing a compressed capacity of 6. The autoloader is compatible with the most popular operating systems and environments supporting a Ultra SCSI-3 LVD interface but requires direct support from the operating system or a compatible backup application to take full advantage of its many features.
The Quantum SuperLoader 3 autoloader is equipped with a LTO-3 tape drive and contains up to sixteen Ultrium 3 data cartridges when utilizing two magazines, providing a compressed capacity of Fibre Channel can support up to devices in a loop configuration. Longwave transceivers with Fibre Channel cable support distances up to 10 kilometers; short pulsewave transceivers with Fibre Channel cable support distances up to meters. The Quantum SuperLoader 3 autoloader is equipped with a LTO-4 tape drive and contains up to sixteen Ultrium 4 data cartridges when utilizing two magazines, providing a compressed capacity of The Quantum SuperLoader 3 VS autoloader is equipped with a Quantum VS tape drive and contains up to sixteen Quantum VS1 data cartridges when utilizing two magazines, providing a compressed capacity of 2.
The autoloader is compatible with the most popular operating systems and environments supporting a SCSI LVD interface but requires direct support from the operating system or a compatible backup application to take full advantage of its many features. The autoloader is compatible with the most popular operating systems and environments supporting a bit Ultra SCSI-3 LVD interface but requires direct support from the operating system or a compatible backup application to take full advantage of its many features.
It is also available as a Fibre Channel data storage device. The autoloader is compatible with the most popular operating systems and environments supporting an Ultra SCSI-3 LVD interface but requires direct support from the operating system or a compatible backup application to take full advantage of its many features.
This chapter covers all aspects of installing the autoloader in your location. The following information is available:. Installing the Fibre Channel autoloader consists of the following steps, which are explained in more detail later in this section:. Power the autoloader on to ensure it passes the power on self-test POST. Note: Locate the AC outlet near the autoloader. The AC power cable is the.
Caution: Excessive dust and debris can damage tapes and tape drives. When installed in a closed multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient.
Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mounting of the equipment in a rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Note: The autoloader is not compatible with a High-voltage. The autoloader is not recommended for use with a RAID controller. If this problem occurs, it is recommended that the autoloader be attached to a separate SCSI bus controller on the host or server.
Before you begin, clear a desk or table so that you have room to unpack the autoloader. Ensure that the work area is free from conditions that could cause electrostatic discharge ESD. Discharge static electricity from your body by touching a known grounded surface, such as your computer's metal chassis.
The Quantum SuperLoader 3 Quick Start Guide included in the packaging describes how to unpack and inspect your autoloader correctly. Unpack your new Quantum SuperLoader 3 autoloader carefully and inspect it for any damage that might have occurred during shipping. If you notice any damage, report it to the shipping company immediately. Set the accessories package aside for now.
Do not set the autoloader on either end or sides. Then remove the bag from the autoloader. To rackmount the autoloader, you need to select an open 2U computer rack location near the server that will host the autoloader.
Caution: Whenever you power cycle the autoloader, allow Note: If the cover must be taken off, there are 26 screws that need to be removed.
Turn off all attached accessory devices, such as printers and other SCSI devices. SCSI terminator. Contact your service representative or your SCSI host adapter manufacturer for information.
Otherwise, attach the cable to the next device on the SCSI bus. Make sure that the last device on the SCSI bus is properly terminated. Turn on any other devices you turned off earlier. Check the LCD screen to make sure the autoloader is receiving power.
If it is not, check the power connections and your power source. When the initialization sequence is complete, the LCD screen displays the Home screen. To connect the Fibre Channel and power cables to the autoloader, follow these steps:.
In addition, follow these general guidelines:. Software compatibility information is available at www. Most backup software packages require an additional module to communicate with the autoloader robotics. Use wrist-grounding straps and anti-static mats when handling internal components. Only the devices physically at the beginning and end of the SCSI bus should be terminated. If the host is located at the beginning of the SCSI bus, the host should already have a terminator installed.
For more information on verifying the connection of SCSI devices, consult the operating system documentation. There are two device drivers associated with the SuperLoader 3 autoloader. One for the autoloader itself, and a second for the tape drive within the autoloader. Note: Device drivers are required if you intend to use the Microsoft Windows native backup application. Commercial backup applications provide all necessary device driver support. Refer to www. The bar code reader is enclosed within the body of the autoloader.
Beyond that, there is no user interface with the bar code reader via the front panel operator controls or LCD screen. The information from each label is stored in memory and available through SCSI and On-board Remote Management to the computer's operating system or backup application upon request.
If utilizing the bar code reader, you must apply or slide the bar code labels into the appropriate slot on the front of each cartridge. A set of bar code labels is initially included with the autoloader. DLTSage Dashboard enables you to more effectively manage and protect your tape storage environment and is accessible from the Windows Start menu and device manager.
The Tape Security feature included in the Dashboard gives you the ability to add an electronic key to tape cartridges. This protects your cartridges from unauthorized access to data in the event that they are lost or stolen. The Dashboard's Status tab quickly and easily displays: your drive and media's current health, a dial that indicates when your drive's next cleaning is due, a graphical display of your cartridge's available free space, and more.
This chapter covers all aspects of autoloader operation. The following topics are available:. Note: If security is enabled and you try to execute a command without entering a password, the autoloader displays the Enter Password screen until you enter a password.
Once you enter a password, the autoloader takes you back to the command screen that you were at prior to entering the password. The front panel consists of two LEDs, four buttons, and a 2-line by 16character LCD screen and provides everything you need to monitor autoloader status and to control all of its functions. All the functionality a ccessed from the scrolling menu is passwordprotected.
Two levels of security are built into the menu. The lower-level security is the operator level and the higher-level security is the administrator level. There is one password for each level. The administrator password allows access to all the functionality available. The operator password allows access to all the functionality in the Command and Status submenus. Many functions on the autoloader may be password-protected to ensure data integrity.
To access the menu items necessary to execute these functions, you must first enter your password. All passwords are six numeric digits long. When you enter a password, all password-protected functionality is available until you close your browser session. If you do not use the front panel for a period of time, the main screen displays on the LCD. When the main screen displays, the autoloader has automatically logged you out. You will have to re-enter your password again to access the menu functionality.
From the main menu, scroll to Commands , and then press Enter. From the Commands submenu, scroll to Log Out , and then press. Session Complete displays on the LCD.
Note: You can also press Escape to log out. Continue pressing.
0コメント